The new Check-Line 3000FX Series coating thickness gauge is a multifunctional fully menu driven gauge for fast, professional and precise coating thickness measurement for

  • varnish, paint and electroplated coatings on iron/steel and
  • varnish, paint and anodising coatings on non-ferrous metals and on austenitic stainless steels


  • All external probes are machined to ultra-high standards and utilize a unique, hard-metal probe tip which prevents probe wear.

    A v-notched footer provides a stable footing on small cylindrical parts, which can be removed to expose a "micro-probe" sensor perfect to measure on small surfaces and parts.

    Where to use 3000FX Series?
    Wherever coatings are applied – whether on visual and aesthetic grounds, to prevent corrosion protection, or for functional and mechanical reasons – the coating thickness represents an essential quality feature. The 3000FX Series is ideal for speedy, non-destructive and exceptionally precise coating thickness measurement.  

    line
    reddot Features
    line
    bluedot The 3000FX Series is a compact, lightweight coating thickness gauge for operators who require both innovative and user-friendly measuring techniques
    bluedot The 3000FX Series ensures non-destructive coating thickness measurement on steel and non Ferrous metals
    bluedot Data transfer to a printer or PC takes place via an infra-red interface
    bluedot Up to 10 000 readings can be statistically evaluated: number of readings, mean value, standard deviation, minimum and maximum reading.
    bluedot The 3000FX Series identifies the substrate and activates the appropriate measuring procedure.
    bluedot Menu in a choice of three languages ensures ease of operation
    bluedot The uniform contact pressure of the sensor is kept to a minimum, preventing scratches and indentations to sensitive surfaces.
    bluedot Optional high temperature footer for measuring on surfaces up to 150 °C/302 °F
    bluedot NIST-Traceable Certificate Included at no additional cost
    bluedot 1 Year Warranty

    line
    reddot Photo Gallery - click any photo to enlarge
    line

     

           


    line
    reddot Complete Kit
    line
     
    The 3000FX Series is supplied as a complete kit with gauge, ferrous and or non-ferrous zero plate(model dependent), 2 calibration standards, 2 AA batteries, hard carrying case, instruction manual and calibration certificate.
    complete kit

    line
    reddot Related Products
    line

    CHE.3000-PTS
    Coating Thickness Gauge Test Stand
    related

    bluedot Spring loaded lever for fast & precise travel

    bluedot  It's Compact size and light weight make it an Ideal test stand for all workplaces

      Click image for more info
    ___________________________________________


    CHE.3000-IRP
    Infra-Red Printer for 3000 Series
    related

    bluedot Infra-Red data transfer

    bluedot 16 lines/second print speed

      Click image for more info
    ___________________________________________


    CHE.TS-5CG
    Commercial Grade Shim Set
    related

      Click image for more info
    ___________________________________________


    CHE.CPS
    Certified Plastic Shims
    related

      Click image for more info

    line
    reddot Dimensions
    line dimensions

    line
    reddot Measuring Limits
    line

    Minimum Radius for Convex Surfaces 0.12" (3 mm)
    Minimum Radius for Concave Surfaces 0.2" (5 mm)
    Minimum Headroom 4" (100 mm)
    Minimum Sample Diameter 0.2" (5 mm)
    Minimum Substrate Thickness - F 20 mils (0.5 mm)
    Minimum Substrate Thickness - NFe 2 mils (50 µm)

    line
    reddot Resolution Table
    line
    Mils
    0.00 - 9.99 mils 0.01 mils
    10.00 - 24.98 mils 0.02 mils
    25.00 - 49.95 mils 0.05 mils
    50.0 - 99.9 mils 0.1 mils
    Microns (µm)
    0.0 - 99.9 µm 0.1 µm
    100.0 - 249.8 µm 0.2 µm
    250.0 - 499.5 µm 0.5 µm
    500 - 999 µm 1 µm
    1.000 - 1.998 mm 0.002 mm

    line
    reddot Specifications
    line
    Measuring principle: magnetic induction principle (Ferrous)
    eddy-current principle (Non-Ferrous) 
    Range 0 - 60.00 mils
    0 - 1500 µm 
    Accuracy ±0.04 mils / 1µm + 1% of reading 
    Resolution Refer to RESOLUTION TABLE, above 
    Display back-light, 4-digit alphanumeric, digit height 10mm 
    Minimum Measuring Area 0.2" x 0.2" (5 mm x 5 mm) 
    Minimum Curvature Radius convex: 0.12" (3 mm), concave: 0.2" (5 mm) 
    Minimum Substrate Thickness Ferrous: 20 mils / 0.5 mm
    Non-Ferrous: 2 mils / 50 µm 
    Calibration factory calibration, zero calibration, foil calibration, offset-function: addition or subtraction of a constant value 
    Memory 80 readings 
    Statistics Program Number of readings, mean value, standard deviation, maximum and minimum reading of max. 10,000 readings 
    Data Output Infrared IrDA Standard  
    Operating Temp. 32 °F - 122 °F / 0 °C - 50 °C 
    Surface Temp. 5° F - 140° F / -15° C - 60° C (standard)
    5° - 302° F / 15° - 150° C (w/optional footer) 
    Storage Temp. -4 °F to 140 °F / -20 °C to +60 °C 
    Power 2 AA 1.5V 
    Dimensions 5.6" x 2.5" x 1.2" (140 mm x 62 mm x 30 mm) 
    Weight 7 oz (200 g) (gauge + probe) 
    Protection Class IP 52 (proof against dust and dripping water)  
    Standards DIN, ISO, ASTM, BS  
    Warranty 1 Year 
    Calibration Certificate Included 


     

    Item Description
    CHE.DCF-3000FX DCF-3000FX Ferrous Only Model Complete Kit
    CHE.DCN-3000FX DCN-3000FX Non-Ferrous Only Model Complete Kit
    CHE.DCFN-3000FX DCFN-3000FX Combination Ferrous and Non-Ferrous Model Complete Kit
    Accessories
    CHE.3000-HTF High Temp Footer
    CHE.3000-PTS Precision Test Stand for 3000FX
    CHE.3000-IRP 3000-IRP Infra-Red Printer
    CHE.3000-IR-USB 3000-IR-USB Infrared Adapter for Data Transfer to PC via USB
     
     

    link to coating thickness gauge index page

    servicing the Canadian provinces of Newfoundland, Nova Scotia, New Brunswick, Prince Edward Island, Quebec, Ontario, Manitoba, Saskatchewan, Alberta ,British Columbia and the states of Alabama, Alaska, Arizona, Arkansas, California, Colorado, Connecticut, Delaware, Florida, Georgia, Hawaii, Idaho, Illinois, Indiana, Iowa, Kansas, Kentucky, Louisiana, Maine, Maryland, Massachusetts, Michigan, Minnesota, Mississippi, Missouri, Montana, Nebraska, Nevada, New Hampshire, New Jersey, New Mexico, New York, North Carolina, North Dakota, Ohio, Oklahoma, Oregon, Pennsylvania, Rhode Island, South Carolina, South Dakota, Tennessee, Texas, Utah, Vermont, Virginia, Washington, West Virginia, Wisconsin,Wyoming We can ship via UPS to Afghanistan , Aland Islands , Albania , Algeria , American Samoa , Andorra , Angola , Anguilla , Antigua & Barbuda , Argentina , Armenia , Aruba , Australia , Austria , Azerbaijan , Azores , Bahamas , Bahrain , Bangladesh , Barbados , Belarus , Belgium , Belize , Benin , Bermuda , Bhutan , Bolivia , Bonaire , Bosnia , Botswana , Brazil , British Virgin Isles , Brunei , Bulgaria , Burkina Faso , Burundi , Cambodia , Cameroon , Canada , Canary Islands , Cape Verde , Cayman Islands , Central African Republic , Chad , Chile , China , Colombia , Comoros , Congo , Cook Islands , Costa Rica , Croatia , Curacao , Cyprus , Czech Republic , Democratic Republic of Congo , Denmark , Djibouti , Dominica , Dominican Republic , Ecuador , Egypt , El Salvador , England , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Faeroe Islands , Fiji , Finland , France , French Guiana , French Polynesia , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Greenland , Grenada , Guadeloupe , Guam , Guatemala , Guernsey , Guinea , Guinea-Bissau , Guyana , Haiti , Holland , Honduras , Hong Kong , Hungary , Iceland , India , Indonesia , Iraq , Ireland , Israel , Italy , Ivory Coast , Jamaica , Japan , Jersey , Jordan , Kazakhstan , Kenya , Kiribati , Kosrae , Kuwait , Kyrgyzstan , Laos , Latvia , Lebanon , Lesotho , Liberia , Libya , Liechtenstein , Lithuania , Luxembourg , Macau , Macedonia (Fyrom) , Madagascar , Madeira , Malawi , Malaysia , Maldives , Mali , Malta , Marshall Islands , Martinique , Mauritania , Mauritius , Mayotte , Mexico , Micronesia , Moldova , Monaco , Mongolia , Montenegro , Montserrat , Morocco , Mozambique , N. Mariana Islands , Namibia , Nepal , Netherlands , Netherlands Antilles , New Caledonia , New Zealand , Nicaragua , Niger , Nigeria , Norfolk Island , Northern Ireland , Norway , Oman , Pakistan , Palau , Panama , Papua New Guinea , Paraguay , Peru , Philippines , Poland , Ponape , Portugal , Puerto Rico , Qatar , Reunion , Romania , Rota , Russia , Rwanda , Saba , Saipan , San Marino , Saudi Arabia , Scotland , Senegal , Serbia , Seychelles , Sierra Leone , Singapore , Slovakia , Slovenia , Solomon Islands , South Africa , South Korea , Spain , Sri Lanka , St. Barthelemy , St. Christopher , St. Croix , St. Eustatius , St. John , St. Kitts & Nevis , St. Lucia , St. Maarten , St. Martin , St. Thomas , St. Vincent/Grenadines , Suriname , Swaziland , Sweden , Switzerland , Syria , Tahiti , Taiwan , Tajikistan , Tanzania , Thailand , Timor Leste , Tinian , Togo , Tonga , Tortola , Trinidad & Tobago , Truk , Tunisia , Turkey , Turkmenistan , Turks & Caicos Islands , Tuvalu , Uganda , Ukraine , Union Island , United Arab Emirates , United Kingdom , United States , Uruguay, US Virgin Islands , Uzbekistan , Vanatu , Vatican City State , Venezuela , Vietnam , Virgin Gorda , Wales , Wallia & Futuna Islands , Western Samoa , Yap , Yemen , Zambia , Zimbabwe